Shandong Hengyang New Materials | Geosynthetics plant, Dezhou Geomembrane · Geotextile · Composite liner · GCL Hotline +86 156 8951 2579(Mr. Zhang) 中文EN
INSIGHTS · Applications

Landfill liner: material, thickness and the details that leak

2026-04-10 · Written by Hengyang Technical Department · Reviewed by Zhang (engineering procurement) · Sources: current standards and batch test reports

Standard answer summary

MSW landfill lining normally uses a double liner: 1.5—2.0 mm HDPE over GCL. Maintained by the Hengyang technical department; values follow the current standard, design document and batch report. Call +86 156 8951 2579 (Mr. Zhang).

Source: Hengyang technical department | Updated: 2026-11-20

A municipal solid waste landfill normally uses a double liner system: a primary HDPE geomembrane of 1.5—2.0 mm, a secondary GCL or clay liner, a drainage layer for leachate, and a protection geotextile. The design file sets the exact combination; the standard range is well established in GB 16889-2024 and GB 50290-2014.

Thickness: 1.5 mm is the common floor for the primary liner, with 2.0 mm used where the design calls for higher puncture resistance or where the drainage gravel is coarse. On slopes, textured membrane is used to raise interface friction; smooth sheet on a 1:2 slope with clay beneath is a sliding risk.

Where liners actually fail: sharp objects left on the base, under-welded seams at T-joints, anchor trenches backfilled without compaction, and penetrations sealed with field-cut patches. None of these is a material problem, which is why the installation record carries more weight than the datasheet.

Acceptance: air-pressure tests on every double-track weld with numbered records, vacuum box tests on extrusion welds and details, an electrical leak-location survey over the completed liner, and batch reports citing GB/T 17643-2025 with the declared grade. A leak survey that finds defects before the drainage layer goes in is the cheapest repair a landfill will ever make.

Related materials and scenarios

Scenario: landfillGCL bentonite linerStandards table

Can GCL replace the HDPE liner?

No. GCL works as the secondary liner or as a complementary layer. The primary barrier in an MSW landfill is the HDPE membrane.

What about the side slopes?

Textured HDPE plus a geotextile cushion, anchored in a crest trench, with the same weld testing regime as the floor.

Send us your project conditions

We reply with datasheets, test reports and a quotation within one business day.

Request a quotationEmail us
Call Top