What is the difference between a geomembrane and a waterproofing membrane?

They are different names for the same family of HDPE flexible lining sheet. Tender documents say geomembrane; pond and aquaculture suppliers say waterproofing membrane. Selection depends on thickness, standard and welding, not on the name.

How do I choose between 0.5 mm and 1.0 mm?

Look at the head of water and the base. Shallow water on a smooth prepared base can use 0.5 mm. Landfill, deeper water or a base with sharp objects needs 1.0 mm or more, with 1.5 mm at critical details.

Can a sheet marked 1.0 mm measure 0.85 mm?

Thickness has a tolerance and the standard allows a defined deviation; beyond the tolerance the batch is non-conforming. Measure several points on arrival, average them and check against the batch report.

What does OIT tell me?

Oxidation induction time reflects resistance to thermo-oxidative ageing. It is a better indicator of the formulation than any claim about how many years the sheet will last.

How is geomembrane welded?

Mainly double-track hot wedge welding. Temperature and speed are set by a trial weld. The sheet and the weld area must be dry; rain and standing water are not acceptable conditions.

How are welds tested?

Double-track welds are pressure tested and the pressure drop observed; single seams and details are checked with a vacuum box. T-joints and anchor zones get particular attention, and test records are archived with the project.

How much material does one square metre of finished lining need?

Calculate from the developed area plus laps and waste. A 10 cm lap is the normal allowance; irregular details and anchor trenches are counted separately.

How is a puncture repaired?

Clean the base, apply a patch that extends beyond the damaged area, weld it hot, and re-test the patch before covering.

Why does a GCL self-heal?

Sodium bentonite swells on contact with water and forms a low-permeability gel in defects and laps, interrupting seepage.

How should drainage net flow capacity be assessed?

Not from the laboratory initial value alone. Apply reductions for site load, clogging and creep; a net that is too thin fails after compaction.

Has GB/T 17643 been revised?

The current edition is GB/T 17643-2025 with grades GH-1, GH-2S, GH-2T1 and GH-2T2. Tenders and purchases should respond to the current edition.

Can we visit the plant?

Yes. The plant is in Lingcheng District, Dezhou, Shandong. You can see the blown film line, coating line, in-line thickness gauging and the laboratory sample store. Please contact us one day ahead.