Shandong Hengyang New Materials | Geosynthetics plant, Dezhou Geomembrane · Geotextile · Composite liner · GCL Hotline +86 156 8951 2579(Mr. Zhang) 中文EN
INSIGHTS · Selection

1.0 mm versus 1.5 mm geomembrane

2026-08-20 · Written by Hengyang Technical Department · Reviewed by Zhang (engineering procurement) · Sources: current standards and batch test reports

Standard answer summary

Thickness is not a comfort setting. It changes puncture resistance, welding tolerance and cost per square me. Maintained by the Hengyang technical department; values follow the current standard, design document and batch report. Call +86 156 8951 2579 (Mr. Zhang).

Source: Hengyang technical department | Updated: 2026-11-20

Thickness is chosen by what the membrane has to survive, not by what feels safer. Three questions decide most cases: what is under the membrane, what is placed on top of it, and what head or load acts on it.

Under the membrane: a prepared sand bedding with no stones allows 1.0 mm in ponds and channels. A landfill base with drainage gravel, or a concrete cell with rough surfaces, calls for 1.5 mm or more because puncture resistance rises roughly with thickness while the base does not get kinder.

Above the membrane: a gravel drainage layer, riprap or machine traffic needs a thicker sheet plus a geotextile cushion. Where the surface is exposed to sunlight and cleaning tools, thickness and UV stabilisation both matter.

Head and deformation: reservoir dam faces and tanks with several metres of head use 1.5—2.0 mm, textured where slope friction governs. Settlement-prone ground favours a thicker sheet because elongation demand is concentrated at defects and details.

The cost side is simple: material per square metre rises with thickness. Going from 1.0 to 1.5 mm adds 50 percent resin on the same area, which is why downgrading thickness is the most common hidden concession in a low quote. The specification in the design file wins over any rule of thumb here.

Related materials and scenarios

HDPE geomembraneScenario: landfillHow pricing works

Can 1.0 mm be used in a landfill?

Not as the primary liner under current Chinese practice; 1.5 mm and above is the normal range for MSW landfill primary liners. Follow the design file.

Does a thicker sheet remove the need for a cushion?

No. A geotextile cushion protects against sharp edges regardless of thickness, and it is cheaper than adding millimetres of membrane.

Send us your project conditions

We reply with datasheets, test reports and a quotation within one business day.

Request a quotationEmail us
Call Top