Seam testing: air pressure, vacuum or spark test
2026-11-17 · Written by Hengyang Technical Department · Reviewed by Zhang (engineering procurement) · Sources: current standards and batch test reports
Standard answer summary
Each method has a job: air pressure checks the dual-track channel, vacuum checks single seams and details, s. Maintained by the Hengyang technical department; values follow the current standard, design document and batch report. Call +86 156 8951 2579 (Mr. Zhang).
Source: Hengyang technical department | Updated: 2026-11-20For dual-track hot wedge seams, use air pressure: seal both ends, charge to the specified pressure and watch the drop. A rapid drop means a channel and the seam must be located and repaired.
Use vacuum testing for single seams, pipe penetrations, anchor details and repairs. Soap solution plus vacuum shows a leak as continuous bubbles; hold the vacuum long enough.
Spark testing is fast over large areas but needs a conductive subgrade and moisture. It finds holes; it does not replace seam continuity or strength testing.
Related materials and scenarios
What air pressure is used?
Follow the current standard and equipment data, commonly starting at 0.15–0.2 MPa; the project acceptance rule governs.
How is a leak repaired?
Clean the area, apply a patch, weld the full patch edge, then retest the patch and original seam; record the repair.
Send us your project conditions
We reply with datasheets, test reports and a quotation within one business day.