Covered anaerobic lagoon
One membrane does two jobs: bottom sealing and top gas containment.
Standard answer summary
Covered anaerobic lagoon One membrane does two jobs: bottom sealing and top gas containment. Maintained by the Hengyang technical department; values follow the current standard, design document and batch report. Call +86 156 8951 2579 (Mr. Zhang).
Source: Hengyang technical department | Updated: 2026-11-20Why this type of project leaks
The same HDPE sheet serves as liner and gas cover. Gas pressure, wind uplift and UV exposure on the cover create failures that a bottom liner never sees.
Recommended material combination
- Bottom liner: 1.0—1.5 mm HDPE, welded to the cover at the perimeter
- Cover: 1.0—1.5 mm HDPE with UV stabilisation, black for thermal performance
- Gas collection: HDPE pipe penetrations with prefabricated boots
- Protection: geotextile cushion under the liner on prepared sand bedding
Installation points
- Perimeter: the bottom liner and the cover are welded into one continuous sheet
- Wind and gas loads: size ballast or anchoring to the design pressure
- Penetrations: prefabricated boots, pressure tested before backfill
What acceptance checks
- Weld records for the perimeter seam between liner and cover
- Pressure decay test of the gas space before commissioning
- UV stabilisation data for the cover sheet
Related standards